BugZero found this defect 1068 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/26/2024
BIG-IP
BIG-IP APM
BIG-IP TMOS
13.1.3.4
13.1.3.5
13.1.3.6
13.1.4
13.1.4.1
13.1.5
13.1.5.1
14.1.2.5
14.1.2.6
14.1.2.7
14.1.2.8
14.1.3
No fixed releases provided.
Symptoms ... Clustered high availability (HA) devices cannot establish ConfigSync connection, and the prompt status reports disconnected. ... MCPD is logging a message similar to this repeatedly, even though all TMMs are up and running: err mcpd[4247]: 0107142f:3: Can't connect to CMI peer 192.0.2.1, TMM outbound listener not yet created ... Impact ... BIG-IP devices are not able to perform ConfigSync operations. ... Conditions ... This can occur under either of the following conditions: -- Some provisioning operations (i.e. provisioning APM), when TMM restarts during the provisioning. ... This has primarily been seen with BIG-IP instances running in Google Cloud. -- Changing the license of a BIG-IP VE when the new license changes the number of TMM instances that will run on the BIG-IP (i.e. upgrading from a 1Gbps to 3Gbps VE license) ... Restart MCPD on the affected system. ... Note: This will disrupt traffic while system services restart. ... Fix Information