BugZero found this defect 328 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/26/2024
BIG-IP
BIG-IP APM
16.1.0
16.1.1
16.1.2
16.1.2.1
16.1.2.2
16.1.3
16.1.3.1
16.1.3.2
16.1.3.3
16.1.3.4
16.1.3.5
16.1.4
No fixed releases provided.
Bug ID 1043249: Misconfigured CA bundle causes a misleading HTTP error message. ... Last Modified: Apr 26, 2024 ... Symptoms ... You see an error in /var/log/ltm: Error in getting Address Space Provider Metadata from the URI <URI name> for the provider <Address space name> and error message is Content length header is missing. ... Impact ... The error message is confusing. ... It really means that the CA bundle is misconfigured. ... Conditions ... Intentionally or mistakenly configuring a wrong "Trusted Certificate Authorities" bundle on a network access address space. ... Workaround ... No workaround