BugZero found this defect 984 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/26/2024
BIG-IP
BIG-IP TMOS
13.0.0
13.0.0 HF1
13.0.0 HF2
13.0.0 HF3
13.0.1
13.1.0
13.1.0.1
13.1.0.2
13.1.0.3
13.1.0.4
13.1.0.5
13.1.0.6
No fixed releases provided.
Bug ID 1045277: The /var partition may become 100% full requiring manual intervention to clear space ... Symptoms ... The /var partition might become completely full on the disk due to files being written to /var/config/rest. ... This condition may be accompanied by console error messages similar to the following: 011d0004:3: Disk partition /var (slot #) has only 0% free on secondary blade. ... Additionally, there may be periodic restjavad and bigd daemons restarts related to disk space exhaustion. ... Impact ... The partition housing /var/config/rest may become 100% full, impacting future disk IO to the partition. ... Workaround ... Important: This workaround is temporary, and may need to be periodically performed either manually or from a script. ... Impact of Workaround: While these steps are performed, the BIG-IP REST API will be temporarily inaccessible, and higher disk IO may be seen. ... Run the following commands, in sequence: bigstart stop restjavad rm -rf /var/config/rest/...