4/26/2024
BIG-IP
BIG-IP TMOS
13.1.0
13.1.0.1
13.1.0.2
13.1.0.3
13.1.0.4
13.1.0.5
13.1.0.6
13.1.0.7
13.1.0.8
13.1.1
13.1.1.2
13.1.1.3
16.1.4
15.1.9
Bug ID 1063237: Stats are incorrect when the management interface is not eth0 ... Last Modified: Apr 26, 2024 ... Severity: 3-Major ... Symptoms ... The provision.managementeth db variable can be used to change which interface the management interface is bridged to: https://clouddocs.f5.com/cloud/public/v1/shared/change_mgmt_nic_google.html If this is changed to something other than eth0, the management interface stats will continue to be read from eth0 and thus be incorrect. ... Impact ... Management interface stats are incorrect. ... Conditions ... When provision.managementeth is changed to something other than eth0. ... Workaround ... Reconfigure the management interface to use eth0