Operational Defect Database

BugZero found this defect 872 days ago.

F5 | 1070393

The f5_api_com.crt certificate file may be removed by the load sys config command

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

15.1.2

15.1.2.1

15.1.3

15.1.3.1

15.1.4

15.1.4.1

15.1.5

15.1.5.1

15.1.6

15.1.6.1

15.1.7

15.1.8

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1070393: The f5_api_com.crt certificate file may be removed by the load sys config command ... Last Modified: Apr 26, 2024 ... Affected Product(s): ... Severity: 3-Major ... Symptoms ... The BIG-IP downloads an f5_api_com.crt certificate file when a production BIG-IP license is installed, but a subsequent "load sys config" reverts to the pre-certificate config, and deletes (tidies up) the file. ... Impact ... F5_api_com.crt certificate file is not present on the BIG-IP system. ... Conditions ... -- Activate a BIG-IP license in either the GUI or tmsh (this causes the f5 API certificate to be downloaded and installed into the config) -- Run 'tmsh load sys config' -- Observe that the f5_api_com.crt object is no longer present in the BIG-IP config. ... Workaround

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

New

Learn More