BugZero found this defect 653 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
5/2/2024
F5OS
F5OS Velos
No affected releases provided.
F5OS-C 1.5.0
If LACP interfaces are configured and used by the tenant, after the partition is disabled/enabled, the LACP interface may not work properly due to wrong interface LACP state, which is caused by the disable/enable process. ... Symptoms: interface state lacp_state is LACP_DEFAULTED For example: interface 2/1.0 is one of member of an LACP interface, which works fine before the partition is disabled/enabled. ... After the partition is disabled/enabled, run "show interfaces interface 2/1.0 state" command; the output is lacp_state LACP_DEFAULTED. ... lacp_state LACP_DEFAULTED is wrong which will cause vlan-listeners missing on the blade. ... Impact ... Tenant will not be able to send/receive user traffic and it will not recover automatically. ... Conditions ... 2. LACP interface is configured correctly and up before the partition is disabled/enabled. ... Workaround ... Remove the ethernet interface from the aggregation and re-attach it to the aggregation. ... This will recover the interfa...