Operational Defect Database

BugZero found this defect 811 days ago.

F5 | 1083405

"Error connecting to named socket" from zrd

Last update date:

5/17/2024

Affected products:

BIG-IP

BIG-IP GTM

BIG-IP TMOS

Affected releases:

14.1.4.5

14.1.4.6

14.1.5

14.1.5.1

14.1.5.2

14.1.5.3

14.1.5.4

14.1.5.6

15.1.5

15.1.5.1

15.1.6

15.1.6.1

Fixed releases:

No fixed releases provided.

Description:

Severity: 3-Major ... Symptoms ... After an mcpd restart, zrd may not be able to re-establish a connection to named. ... This shows up in the /var/log/gtm file or in the GUI with a message similar to the following: err zrd[27809]: 01150306:3: Error connecting to named socket 'Connection refused'. ... (or) err zrd[16198]: 01150306:3: Error connecting to named socket 'Connection timed out'. ... Impact ... Looking up or modifying zone records may fail. ... Conditions ... After an mcpd restart

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Resolved