4/26/2024
BIG-IP
BIG-IP LTM
11.6.0
11.6.1
11.6.2
11.6.3
11.6.3.1
11.6.3.2
11.6.3.3
11.6.3.4
11.6.4
11.6.5
11.6.5.1
11.6.5.2
No fixed releases provided.
Bug ID 1093061: MCPD restart on secondary blade during hot-swap of another blade ... Last Modified: Apr 26, 2024 ... Symptoms ... In rare instances, inserting a new blade into a VIPRION system can trigger a config error on another secondary blade due to attempting to delete the old blade's physical disk while it is still "in use": err mcpd[7965]: 01070265:3: The physical disk (S3F3NX0J902788) cannot be deleted because it is in use by a disk bay (1). ... err mcpd[7965]: 01070734:3: Configuration error: Configuration from primary failed validation: 01070265:3: The physical disk (S3F3NX0J902788) cannot be deleted because This causes MCPD to restart on the secondary blade due to the config error. ... Impact ... -- MCPD restarts on the secondary blade other than the blade that was replaced. ... The config error triggering this is due to an issue with the cluster syncing process between blades; however, the config issue is temporary, and should be resolved after mcpd restarts on the secon...