Operational Defect Database

BugZero found this defect 500 days ago.

F5 | 1095989

PEM behaviour on receiving CCA with result code: 4012 and FUA on the Gy interface

Last update date:

5/3/2024

Affected products:

BIG-IP

BIG-IP PEM

Affected releases:

13.1.0

13.1.0.1

13.1.0.2

13.1.0.3

13.1.0.4

13.1.0.5

13.1.0.6

13.1.0.7

13.1.0.8

13.1.1

13.1.1.2

13.1.1.3

Fixed releases:

17.1.0

16.1.4

Description:

When receiving Gy CCA Multi-Services-Credit-Control.Result-code:4012 (Diameter_Credit_Limit_Reached),Final-Unit-Action (Redirect) and "Redirect-Server-address" is NOT installed on the PEM session. ... Impact ... The action specified in FUI does not get applied to the session. ... Quota management will not work properly for the session. ... Conditions ... Session quota information is passed from OCS to PCEF on the Gy interface. ... Workaround ... None ... Fix Information ... For the case where the PEM receives a CCA with a result code: 4012 and FUI, added changes to install FUA on the session. ... Behavior Change

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Verified

Learn More