F5OS BIG-IP tenants perform an MCPD "forceload" operation after a reboot

Last update date:

5/18/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

14.1.3

14.1.3.1

14.1.4

14.1.4.1

14.1.4.2

14.1.4.3

14.1.4.4

14.1.4.5

14.1.4.6

14.1.5

14.1.5.1

14.1.5.2

Fixed releases:

No fixed releases provided.

Description:

Severity: 3-Major ... Symptoms ... BIG-IP tenant software running on an F5OS device performs an MCPD "forceload" operation after a reboot which means the MCPD loads the configuration from the text config file rather than the binary database. /var/log/ltm contains chmand Hardware/Chassis change detected. ... Forcing db load from the file. ... Impact ... -- Devices report "changes pending" after the tenant is rebooted. -- This may result in configuration loss if auto-sync is configured. -- This may result in configuration loss as a result of operational foul-ups, regardless of which device had a newer configuration before one was rebooted, the newly-rebooted device will claim to have a newer configuration. ... Conditions ... The management Mac address transfers from F5OS to BIG-IP tenant are not in sync. ... Workaround ... None