Operational Defect Database

BugZero found this defect 724 days ago.

F5 | 1107453

Performance drop observed in some Ramcache::HTTP tests on BIG-IP i10800 platform

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP LTM

Affected releases:

16.1.0

16.1.1

16.1.2

16.1.2.1

16.1.2.2

16.1.3

16.1.3.1

16.1.3.2

16.1.3.3

16.1.3.4

16.1.3.5

16.1.4

Fixed releases:

No fixed releases provided.

Description:

Drop in TPS of around 6.5% observed for Ramcache::HTTP tests. ... Impact ... Delay in client side response during peak traffic flow due to lowered throughput. ... Conditions ... - BIG-IP i10800 l7-performance-fpga platform - 5KB file size with 1 Request Per Connection - 5KB file size with 100 Request Per Connection Virtual server with the following profiles - 1. http 2. tcp profile with nagle disabled 3. web acceleration profile with following attributes - - cache-max-age 36000 - cache-object-max-size 1500001 - cache-object-min-size 1