Operational Defect Database

BugZero found this defect 719 days ago.

F5 | 1110653

Network Access Launch Application feature may not work properly if parameters have '&' (ampersand) in them.

Last update date:

5/9/2024

Affected products:

APM-Clients

APM-Clients APM

Affected releases:

7.2.1.3

7.2.1.4

7.2.1.5

7.2.2

7.2.2.1

7.2.2.2

7.2.3

7.2.3.1

7.2.4

7.2.4.2

7.2.4.3

7.2.4.4

Fixed releases:

No fixed releases provided.

Description:

Severity: 4-Minor ... Symptoms ... Launched applications may fail as the parameters will be truncated at the first occurrence of '&' (a pop-up window will show the truncated parameters). ... Impact ... Launched application may fail. ... Conditions ... Network Access Resource Launch Application feature with '&' characters (either static parameters or inside session variables). ... Workaround ... If Launch application is related to drive mapping (e.g., Application launch is equivalent to "net use X: param1 param2 etc."), Network Access built-in feature of "Drive Mappings" can be used (this feature automatically uses same credentials that were used to authenticate with APM for back-end drive mapping SSO). ... Fix Information ... None