5/3/2024
BIG-IP
BIG-IP TMOS
14.1.4.4
14.1.4.5
14.1.4.6
14.1.5
14.1.5.1
14.1.5.2
14.1.5.3
14.1.5.4
14.1.5.6
16.1.2.2
16.1.3
16.1.3.1
17.1.1
16.1.4
15.1.10
Bug ID 1117609: VLAN guest tagging is not implemented for CX4 and CX5 on ESXi ... Last Modified: May 03, 2024 ... Impact ... Host-side tagging is required. ... Conditions ... Workaround ... If only one VLAN is required, use host-side tagging and set the VLAN to "untagged" in the BIG-IP guest. ... If multiple VLANs are required, use the "sock" driver instead. ... Edit the /config/tmm_init.tcl file and restart the Virtual Edition (VE) instance. ... Network traffic is disrupted while the system restarts. ... echo "device driver vendor_dev 15b3:1016 sock" >> /config/tmm_init.tcl CPU utilization may increase as a result of switching to the sock driver.