BugZero found this defect 697 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/26/2024
BIG-IP
BIG-IP WAM
16.0.0
16.0.0.1
16.0.1
16.0.1.1
16.0.1.2
16.1.0
16.1.1
16.1.2
16.1.2.1
16.1.2.2
16.1.3
16.1.3.1
No fixed releases provided.
Bug ID 1117693: TMM restarts in loop when WAM applications attached to the default /common/webacceleration profile ... Last Modified: Apr 26, 2024 ... Affected Product(s): ... Severity: 2-Critical ... Symptoms ... If the default /common/webacceleration profile is modified to have WAM applications attached, the internal APM apm-enduser-if-cache profile which is forced onto APM virtual servers will cause TMM to attempt to activate WAM - this fails with TMM in a recursive stack loop. ... Impact ... Traffic disrupted while tmm restarts.