Operational Defect Database

BugZero found this defect 697 days ago.

F5 | 1120345

Running tmsh load sys config verify can trigger high availability (HA) failover

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP All

Affected releases:

12.1.0

12.1.1

12.1.2

12.1.3

12.1.3.1

12.1.3.2

12.1.3.3

12.1.3.4

12.1.3.5

12.1.3.6

12.1.3.7

12.1.4

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1120345: Running tmsh load sys config verify can trigger high availability (HA) failover ... Last Modified: Apr 26, 2024 ... Severity: 3-Major ... Symptoms ... When running tmsh 'load sys config verify' on a config that contains both an high availability (HA) group and a traffic group referencing that high availability (HA) group, this will trigger an high availability (HA) fault and failover. ... Impact ... HA fault and failover. ... - Running 2 BIG-IP systems in an high availability (HA) pair - Run tmsh 'load sys config verify' on a config with the following conditions: - Config to be verified contains an high availability (HA) group - Config to be verified also contains a traffic group referencing the high availability (HA) group ... Workaround ... No workaround currently known, but the failover fault can be cleared by running tmsh 'load sys config' on the system that had 'load sys config verify' run on it. ... Fix Information ... None