Operational Defect Database

BugZero found this defect 687 days ago.

F5 | 1121013

A blade enters a failed state and traffic across the chassis is disrupted.

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP LTM

Affected releases:

17.1.0

17.1.0.1

17.1.0.2

17.1.0.3

17.1.1

17.1.1.1

17.1.1.2

17.1.1.3

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1121013: A blade enters a failed state and traffic across the chassis is disrupted. ... Last Modified: Apr 26, 2024 ... Traffic across the entire chassis will be disrupted. /var/log/ltm will show a message from clusterd such as "Marking slot <nr> SS_FAILED". ... Impact ... Traffic will not be forwarded across the entire chassis. ... Conditions ... -- A chassis platform. -- Clusterd heartbeats from a remote blade fail to arrive. ... This can happen for many reasons such as Linux kernel driver issues. ... Workaround ... Reboot the blade in the failed state. ... Fix Information

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

New

Learn More

Search:

...