4/26/2024
BIG-IP
BIG-IP TMOS
15.1.5
15.1.5.1
15.1.6
15.1.6.1
15.1.7
15.1.8
15.1.8.1
15.1.8.2
15.1.9
15.1.9.1
15.1.10
15.1.10.2
No fixed releases provided.
Bug ID 1121633: Management route lost after reboot when default route is named something other than "default" ... Last Modified: Apr 26, 2024 ... Symptoms ... When the default route name is changed to something other than "default", this results in the management route being lost after reboot, leading to no access to BIG-IP systems via the management address. ... Impact ... After rebooting, the default route via the management interface no longer exists in the routing table. ... BIG-IP administrators are unable to connect to BIG-IP Virtual Edition via the management address. ... Conditions ... Workaround ... Use either of the following workarounds: -- Delete the route completely and reinstall the route. -- Restart mcpd: bigstart restart mcpd ... Fix Information