Operational Defect Database

BugZero found this defect 675 days ago.

F5 | 1124457

APMD can get stuck in an infinite loop when receiving a large post message

Last update date:

5/3/2024

Affected products:

BIG-IP

BIG-IP APM

Affected releases:

14.1.5

14.1.5.1

14.1.5.2

14.1.5.3

14.1.5.4

14.1.5.6

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1124457: APMD can get stuck in an infinite loop when receiving a large post message ... Last Modified: May 03, 2024 ... Severity: 3-Major ... Symptoms ... Client requests sent to BIG-IP are stuck or failed with a 500 HTTP status code. ... Impact ... Client requests are stuck or failed. ... Conditions ... APM policy needs to be associated with the virtual server and a large post message needs to be sent to the virtual server over unauthenticated sessions. ... Workaround ... None

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

New

Learn More