Operational Defect Database

BugZero found this defect 668 days ago.

F5 | 1124865

Removal of LAG member from an active LACP trunk on r2k and r4k systems requires tmm restart

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP LTM

Affected releases:

17.1.0

17.1.0.1

17.1.0.2

17.1.0.3

17.1.1

17.1.1.1

17.1.1.2

17.1.1.3

Fixed releases:

15.1.9

Description:

Bug ID 1124865: Removal of LAG member from an active LACP trunk on r2k and r4k systems requires tmm restart ... Last Modified: Apr 26, 2024 ... Symptoms ... Removal of LAG member from an active LACP trunk stops the traffic flow to the tenant launched on R2x00/R4x00 based appliances. ... Impact ... Traffic flow gets impacted and the system misses the packets routed onto the LACP trunk from where the LAG member was removed. ... Conditions ... - Remove the LAG member using the confd CLI - Restart tmm on all tenants that are associated with the trunk ... Fix Information ... When removing a LAG member from an Active LACP trunk stops traffic flow on an R2x00/R4x00 appliance system, restarting tmm in the tenants resolves the issue. ... Behavior Change