BugZero found this defect 132 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/26/2024
BIG-IP
BIG-IP TMOS
17.1.0
17.1.0.1
17.1.0.2
17.1.0.3
17.1.1
17.1.1.1
17.1.1.2
17.1.1.3
No fixed releases provided.
Symptoms ... A database held in hardware (TCAM), shared between tenants, has a limit that is exceeded by software in tenants that adds and manages entries in the database. ... Symptomatic logs on tenant: in /var/log/ltm, repeating logs such as: err tmm[635]: 01010331:3: Neuron client neuron_client_pva_hwl failed with rule request submit(client connection is busy (has outstanding requests)) in /var/log/tmm, cycles of this group of logs: notice neuron_client_negotiate: Neuron client connection established notice [DDOS Neuron]Neuron daemon started notice hudproxy_neuron_client_closed_cb: Neuron client connection terminated notice [DDOS Neuron]Neuron daemon stopped For F5OS ... host, in partition /var/F5/partitionX/log/velos.log ) repeating logs such as: tcam-manager[41]: priority="Err" version=1.0 msgid=0x6b01000000000007 msg="ERROR" MSG="TCAM processing Error(-5) executing:TCAM_INSERT for ruleno:0x20000000937" Note msgid and ruleno may vary, but Error(-5) is a symptom of this issue.