Operational Defect Database

BugZero found this defect 132 days ago.

F5 | 1128033

Neuron client constantly logs errors when TCAM database is full

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

17.1.0

17.1.0.1

17.1.0.2

17.1.0.3

17.1.1

17.1.1.1

17.1.1.2

17.1.1.3

Fixed releases:

No fixed releases provided.

Description:

Symptoms ... A database held in hardware (TCAM), shared between tenants, has a limit that is exceeded by software in tenants that adds and manages entries in the database. ... Symptomatic logs on tenant: in /var/log/ltm, repeating logs such as: err tmm[635]: 01010331:3: Neuron client neuron_client_pva_hwl failed with rule request submit(client connection is busy (has outstanding requests)) in /var/log/tmm, cycles of this group of logs: notice neuron_client_negotiate: Neuron client connection established notice [DDOS Neuron]Neuron daemon started notice hudproxy_neuron_client_closed_cb: Neuron client connection terminated notice [DDOS Neuron]Neuron daemon stopped For F5OS ... host, in partition /var/F5/partitionX/log/velos.log ) repeating logs such as: tcam-manager[41]: priority="Err" version=1.0 msgid=0x6b01000000000007 msg="ERROR" MSG="TCAM processing Error(-5) executing:TCAM_INSERT for ruleno:0x20000000937" Note msgid and ruleno may vary, but Error(-5) is a symptom of this issue.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

New

Learn More

Search:

...