5/3/2024
F5OS
F5OS F5OS
F5OS Install/Upgrade
F5OS-C 1.5.0
F5OS-C 1.6.0
F5OS-C 1.5.1
Bug ID 1133985: Controller upgrade from 1.4.0 to 1.5.0 caused the partition to go into failed state. ... Symptoms ... After an upgrade of the system controller, the chassis partition went into a failed state. ... syscon-1-active# show partitions partition default RUNNING BLADE OS SERVICE PARTITION SERVICE STATUS NAME ID VERSION VERSION CONTROLLER STATUS VERSION AGE ... Impact ... The partition management software goes into a failed state and the chassis partition cannot be managed. ... Conditions ... Upgrade to v1.5.0 causes the chassis partition to go into a failed state. ... Workaround ... Rebooting the failed controller after upgrade or restarting "vcc partition software manager" service fixes the issue. ... This issue is not reproducible and will be investigated further.