Operational Defect Database

BugZero found this defect 580 days ago.

F5 | 1162221

Probing decision will skip local GTM upon reboot if net interface is not brought up soon enough

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP DNS

BIG-IP GTM

Affected releases:

14.1.0

14.1.0.1

14.1.0.2

14.1.0.3

14.1.0.5

14.1.0.6

14.1.2

14.1.2.1

14.1.2.2

14.1.2.3

14.1.2.4

14.1.2.5

Fixed releases:

15.1.10

Description:

Bug ID 1162221: Probing decision will skip local GTM upon reboot if net interface is not brought up soon enough ... Last Modified: Apr 26, 2024 ... Affected Product(s): ... Symptoms ... Resources will be marked timed out. ... Impact ... Conditions ... iQuery connection between local gtmd and big3d is not established before probing decision is made. ... Workaround ... Modify max-synchronous-monitor-requests to a new value which will trigger probing decision re-evaluation. ... Fix Information