Operational Defect Database

BugZero found this defect 552 days ago.

F5 | 1188141

Tenant launch gets stuck due to un-initialization of VFs under one or more PF

Last update date:

5/17/2024

Affected products:

F5OS

F5OS F5OS

Affected releases:

F5OS-A 1.3.1

F5OS-A 1.3.2

Fixed releases:

F5OS-A 1.4.0

Description:

Bug ID 1188141: Tenant launch gets stuck due to un-initialization of VFs under one or more PF ... Last Modified: May 17, 2024 ... Impact ... Tenant launch will be unsuccessful and is not able to connect to the tenant console or over tenant's management connection. ... Conditions ... 2. The VFs were not created under one or more PFs. 3. ... ================================================== ... 1. From second step in Workaround #1, if the PF wasn't detected in "/sys/class/net" even after a 20 minute duration, reboot the host to trigger the device probing. ... Fix Information ... The workarounds should fix the tenants' statuses and move them to a running state. ... Behavior Change

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Not Verified

Learn More

Search:

...