Race condition processing network failover heartbeats with timeout of 1 second

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

15.1.0

15.1.0.1

15.1.0.2

15.1.0.3

15.1.0.4

15.1.0.5

15.1.1

15.1.2

15.1.2.1

15.1.3

15.1.3.1

15.1.4

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1217077: Race condition processing network failover heartbeats with timeout of 1 second ... Last Modified: Apr 26, 2024 ... Impact ... A failover event could impact traffic flow. ... Conditions ... - HA configuration network failover configured - DB variable 'failover.nettimeoutsec' set to a value of 1 second. ... Workaround ... Following recommended practices of configuring network failover addresses using both the Management IP and Self IP addresses will reduce the chances of initiating a failover. ... Log messages may still be observed. ... Setting the DB variable 'failover.nettimeoutsec' to a value of 2 or greater should avoid the issue. ... Fix Information