Operational Defect Database

BugZero found this defect 464 days ago.

F5 | 1235413

Edge Client stuck in initializing when 'HTTP' is used in OS proxy setting

Last update date:

5/4/2024

Affected products:

APM-Clients

APM-Clients APM

APM-Clients Install/Upgrade

Affected releases:

16.1.2

16.1.2.1

16.1.2.2

16.1.3

16.1.3.1

16.1.3.2

16.1.3.3

16.1.3.4

16.1.3.5

16.1.4

16.1.4.1

16.1.4.2

Fixed releases:

7.2.4.6

Description:

The Windows Edge Client is stuck in initializing. ... Impact ... The first time you save the setting it works; however, the second time you save, the letters "http://" are added to the beginning of the proxy server string, and subsequent attempts to use the edge client will fail. ... Conditions ... Configuring Windows proxy settings in Windows. ... 5. Close the settings window. ... Workaround ... Manually remove the HTTP string for the local proxy IP setting and save. ... Fix Information ... The HTTP string is removed automatically when retrieving the proxy setting from Windows proxy settings. ... Behavior Change