Operational Defect Database

BugZero found this defect 432 days ago.

F5 | 1253449

After publishing, the draft LTM policy configuration might not be updated (intermittently) into the bigip.conf

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

14.1.0

14.1.0.1

14.1.0.2

14.1.0.3

14.1.0.5

14.1.0.6

14.1.2

14.1.2.1

14.1.2.2

14.1.2.3

14.1.2.4

14.1.2.5

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1253449: After publishing, the draft LTM policy configuration might not be updated (intermittently) into the bigip.conf ... Last Modified: Apr 26, 2024 ... Symptoms ... Publishing LTM draft policy and "save config" operations are not atomic, hence there exists a race condition. ... When the latter happens first, then the issue is observed otherwise the LTM draft policy is successfully updated into the bigip.conf file. ... Impact ... Published LTM draft policies are reverted to the draft state. ... Conditions ... - Execute the command "tmsh load /sys config current-partition" or the existing system configuration is loaded from bigip.conf after publishing the draft LTM policy. ... Workaround ... Perform any of the below-mentioned steps immediately after successfully publishing an LTM draft policy: - Execute the command "tmsh save /sys config current-partition" on the BIG-IP shell.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

New

Learn More