Operational Defect Database

BugZero found this defect 33 days ago.

F5 | 1288921

Windows logon integration is still using User-Agent as IE7.

Last update date:

4/25/2024

Affected products:

APM-Clients

APM-Clients TMOS

Affected releases:

No affected releases provided.

Fixed releases:

7.2.4.4

Description:

The Winlogon Integration client component in BIG-IP Edge Client sends IE7 User Agent String. ... Impact ... Some external IDP's or Logon pages may consider our browser as a old IE7 based one and might reject the requests. ... Conditions ... IE7 user Agent will be seen when requests are sent from WinLogon Client to the server ... Workaround ... 1. Launch a command prompt with administrator privilege and run regedit 2. ... Navigate to: Computer\HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Microsoft\Internet Explorer\Main\FeatureControl\FEATURE_BROWSER_EMULATION 3. ... Right Click -> New -> DWORD (32-bit) Value => F5LogonUI.exe 4.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Resolved

Learn More