5/8/2024
BIG-IP
BIG-IP TMOS
14.1.0
14.1.0.1
14.1.0.2
14.1.0.3
14.1.0.5
14.1.0.6
14.1.2
14.1.2.1
14.1.2.2
14.1.2.3
14.1.2.4
14.1.2.5
No fixed releases provided.
Bug ID 1289845: Pool member marked as offline while matching both receive string and receive disable strings ... The monitor is marked offline when the expected state is up/available. ... Impact ... The monitor is marked offline potentially impacting traffic to the pool when the health monitor is matching both receive and receive disable strings. ... Conditions ... - Monitor configured to monitor in TMM. - Monitor configured with receive string and receive disable string. - Monitor associated with a member where the response to the health monitor matches the receive string and receive disable string and the member is marked as offline. ... Workaround ... Configure the monitor such that the response does not match both the receive and receive disable strings at the same time. ... Alternatively, adjust the receive and receive disable strings such that they will not match at the same time. ... Fix Information