Operational Defect Database

BugZero found this defect 158 days ago.

F5 | 1289845

Pool member marked as offline while matching both receive string and receive disable strings

Last update date:

5/8/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

14.1.0

14.1.0.1

14.1.0.2

14.1.0.3

14.1.0.5

14.1.0.6

14.1.2

14.1.2.1

14.1.2.2

14.1.2.3

14.1.2.4

14.1.2.5

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1289845: Pool member marked as offline while matching both receive string and receive disable strings ... The monitor is marked offline when the expected state is up/available. ... Impact ... The monitor is marked offline potentially impacting traffic to the pool when the health monitor is matching both receive and receive disable strings. ... Conditions ... - Monitor configured to monitor in TMM. - Monitor configured with receive string and receive disable string. - Monitor associated with a member where the response to the health monitor matches the receive string and receive disable string and the member is marked as offline. ... Workaround ... Configure the monitor such that the response does not match both the receive and receive disable strings at the same time. ... Alternatively, adjust the receive and receive disable strings such that they will not match at the same time. ... Fix Information