F5 | 1301897

DAG transition does not complete when TMM starts in FORCED_OFFLINE mode

Last update date:

5/17/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

14.1.0

14.1.0.1

14.1.0.2

14.1.0.3

14.1.0.5

14.1.0.6

14.1.2

14.1.2.1

14.1.2.2

14.1.2.3

14.1.2.4

14.1.2.5

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1301897: DAG transition does not complete when TMM starts in FORCED_OFFLINE mode ... Last Modified: May 17, 2024 ... Symptoms ... When TMM restarts with force-offline enabled, it comes up waiting for a dag_transition. ... It never completes because CDP proxy never comes up due to no active traffic group in FORCE_OFFLINE mode. ... Impact ... Tenants show high CPU and idle enforcer constantly starting or exiting. ... Conditions ... Workaround ... Do not perform upgrade/restart in force-offline mode. ... Fix Information

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

New

Learn More