F5 | 1304289

Pool member monitored by both GTM and LTM monitors may be erroneously marked Down

Last update date:

5/1/2024

Affected products:

BIG-IP

BIG-IP DNS

BIG-IP GTM

BIG-IP LTM

Affected releases:

13.1.0

13.1.0.1

13.1.0.2

13.1.0.3

13.1.0.4

13.1.0.5

13.1.0.6

13.1.0.7

13.1.0.8

13.1.1

13.1.1.2

13.1.1.3

Fixed releases:

17.1.1

Description:

Bug ID 1304289: Pool member monitored by both GTM and LTM monitors may be erroneously marked Down ... Last Modified: May 01, 2024 ... Symptoms ... A GTM or LTM pool member may occasionally be marked Down in error if it is being monitored by the same type of monitor with the same name as another LTM or GTM pool member with the same address and port. ... Impact ... A GTM or LTM pool member may occasionally be marked Down in error. ... Conditions ... name (exact match). ... Workaround ... To work around this issue, assign different names to GTM versus LTM health monitors of the same time (from the list of types above) that are used to monitor pool members for different modules with the same address and port values. ... Fix Information ... None