BugZero found this defect 339 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/26/2024
BIG-IP
BIG-IP TMOS
17.1.0.1
17.1.0.2
17.1.0.3
17.1.1
17.1.1.1
17.1.1.2
17.1.1.3
No fixed releases provided.
Bug ID 1305273: Licensing may fail on AWS 1nic deployments with invalid objects in the config ... Last Modified: Apr 26, 2024 ... Running get_doessier may fail with the following error: get_dossier -b 12345 <131>May 23 12:32:46 bigip1 get_dossier[14203]: 01170003:3: halGetDossier returned error (1): Dossier generation failed. ... Impact ... The BIG-IP system will not be able to generate a license dossier and licensing will fail. ... Conditions ... -- BIG-IP Virtual Edition for AWS -- 1nic configuration -- A config with invalid or unlicensed objects. ... Workaround ... Remove the invalid objects from the config, reboot and re-license the BIG-IP. ... Provision another NIC so that 1nic is not used. ... Fix Information