F5 | 1313333

SNMP DCA or WMI monitors cannot be edited using the GUI

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

15.1.7

15.1.8

15.1.8.1

15.1.8.2

15.1.9

15.1.9.1

15.1.10

15.1.10.2

15.1.10.3

15.1.10.4

17.1.0

17.1.0.1

Fixed releases:

No fixed releases provided.

Description:

Severity: 3-Major ... Symptoms ... Attempting to update snmp_dca or WMI monitors fails with java.lang.NullPointerException. ... Impact ... You are unable to edit or modify SNMP DCA or WMI monitors via the GUI ... Conditions ... -- A new snmp dca or WMI monitor has been created -- Using the GUI to make a change to the monitor ... Workaround ... Use the command line interface or edit the configuration in advanced shell and run tmsh load merge. ... Fix Information ... None