BugZero found this defect 300 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/26/2024
BIG-IP
BIG-IP LTM
14.1.0
14.1.0.1
14.1.0.2
14.1.0.3
14.1.0.5
14.1.0.6
14.1.2
14.1.2.1
14.1.2.2
14.1.2.3
14.1.2.4
14.1.2.5
No fixed releases provided.
Bug ID 1322117: FastL4 TCP PVA accelerated connection might not be cleared until idle timeout. ... Last Modified: Apr 26, 2024 ... Affected Product(s): ... Severity: 4-Minor ... Symptoms ... Connection where client is re-using the source port connecting to a server in TIME_WAIT might not be cleared immediately from BIG-IP connection table after the closure. ... Impact ... Connection will remain in the BIG-IP connection table until idle-timeout is reached. ... Conditions ... -- FastL4 PVA acceleration at Embryonic. -- Client re-using 4-tuple, hitting server in TIME_WAIT.