Operational Defect Database

BugZero found this defect 300 days ago.

F5 | 1322117

FastL4 TCP PVA accelerated connection might not be cleared until idle timeout.

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP LTM

Affected releases:

14.1.0

14.1.0.1

14.1.0.2

14.1.0.3

14.1.0.5

14.1.0.6

14.1.2

14.1.2.1

14.1.2.2

14.1.2.3

14.1.2.4

14.1.2.5

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1322117: FastL4 TCP PVA accelerated connection might not be cleared until idle timeout. ... Last Modified: Apr 26, 2024 ... Affected Product(s): ... Severity: 4-Minor ... Symptoms ... Connection where client is re-using the source port connecting to a server in TIME_WAIT might not be cleared immediately from BIG-IP connection table after the closure. ... Impact ... Connection will remain in the BIG-IP connection table until idle-timeout is reached. ... Conditions ... -- FastL4 PVA acceleration at Embryonic. -- Client re-using 4-tuple, hitting server in TIME_WAIT.