Operational Defect Database

BugZero found this defect 300 days ago.

F5 | 1322497

GTM monitor recv string with special characters causes frequent iquery reconnects

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

14.1.5.4

14.1.5.6

15.1.9

15.1.9.1

15.1.10

15.1.10.2

15.1.10.3

15.1.10.4

16.1.3.5

16.1.4

16.1.4.1

16.1.4.2

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1322497: GTM monitor recv string with special characters causes frequent iquery reconnects ... Last Modified: Apr 26, 2024 ... Affected Product(s): ... Severity: 2-Critical ... Symptoms ... Resources flap, frequent iquery reconnects occur. ... Logs similar to this: err gtmd[12952]: 011ae0fa:3: iqmgmt_receive: SSL error: SSL read (6) err gtmd[12952]: 011ae0fa:3: During SSL shutdown: SSL error: SSL_ERROR_SYSCALL (5) err gtmd[12952]: 011ae0fa:3: iqmgmt_receive: SSL error: SSL read (6) err gtmd[12952]: 011ae0fa:3: During SSL shutdown: SSL error: SSL_ERROR_SYSCALL (5) 012b2004:4: XML parsing error not well-formed (invalid token) at line 3810 012b2004:4: XML parsing error not well-formed (invalid token) at line 7719 012b2004:4: XML parsing error ... not well-formed (invalid token) at line 16837 012b2004:4: XML parsing error not well-formed (invalid token) at line 298