BugZero found this defect 300 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/26/2024
BIG-IP
BIG-IP TMOS
14.1.5.4
14.1.5.6
15.1.9
15.1.9.1
15.1.10
15.1.10.2
15.1.10.3
15.1.10.4
16.1.3.5
16.1.4
16.1.4.1
16.1.4.2
No fixed releases provided.
Bug ID 1322497: GTM monitor recv string with special characters causes frequent iquery reconnects ... Last Modified: Apr 26, 2024 ... Affected Product(s): ... Severity: 2-Critical ... Symptoms ... Resources flap, frequent iquery reconnects occur. ... Logs similar to this: err gtmd[12952]: 011ae0fa:3: iqmgmt_receive: SSL error: SSL read (6) err gtmd[12952]: 011ae0fa:3: During SSL shutdown: SSL error: SSL_ERROR_SYSCALL (5) err gtmd[12952]: 011ae0fa:3: iqmgmt_receive: SSL error: SSL read (6) err gtmd[12952]: 011ae0fa:3: During SSL shutdown: SSL error: SSL_ERROR_SYSCALL (5) 012b2004:4: XML parsing error not well-formed (invalid token) at line 3810 012b2004:4: XML parsing error not well-formed (invalid token) at line 7719 012b2004:4: XML parsing error ... not well-formed (invalid token) at line 16837 012b2004:4: XML parsing error not well-formed (invalid token) at line 298