4/26/2024
BIG-IP
BIG-IP AFM
17.1.0.2
17.1.0.3
17.1.1
17.1.1.1
17.1.1.2
17.1.1.3
No fixed releases provided.
Bug ID 1324197: The action value in a profile which is in different partition cannot be changed from accept/reject/drop to Don't Inspect in UI ... Last Modified: Apr 26, 2024 ... Affected Product(s): ... Severity: 3-Major ... Symptoms ... When trying to change the action value of signature/compliance in an IPS Profile from accept/reject/drop to Don't Inspect in UI, it is not changing. ... This happens when the IPS Profile is in different partition ... Impact ... Will not be able to change the action value from accept/reject/drop to Don't Inspect in UI when the IPS Profile is in different partition ... Conditions ... 1) Create a partition System > Users > Partitions List > Create > give profile_name > update 2) Move to the new partition created at the top right corner of UI 3) Create IPS Profile Security > Protocol Security > Inspection Profiles > Add > New > give Profile name > select the services > update action values of signatures and compliances to accept/reject/drop 4) Change t...