4/26/2024
BIG-IP
BIG-IP SSLO
15.0.0
15.0.1
15.0.1.1
15.0.1.2
15.0.1.3
15.0.1.4
15.1.0
15.1.0.1
15.1.0.2
15.1.0.3
15.1.0.4
15.1.0.5
No fixed releases provided.
Bug ID 1324297: SSL Orchestrator GUI goes into a bad state if trying to save a configuration that involves an item with reference to a block id that does not exist ... Symptoms ... When trying to update or create a topology that involves a dependency in f5-sslo-orchestrator-dg-data where the self link points to a block that does not exist, the GUI will not move to the next page, and will disable both Save buttons. ... Impact ... The GUI will leave both save buttons disabled until the operation is canceled, and the particular item with the missing id cannot be used in any topology. ... Conditions ... An item in f5-sslo-orchestrator-dg-data has a self link to a missing block id. ... Workaround ... The f5-sslo-orchestrator-dg-data app needs to be cleaned so that the item no longer has a self link to a missing block id. ... Fix Information