Operational Defect Database

BugZero found this defect 283 days ago.

F5 | 1325681

VLAN tscookies with fastl4 timestamp preserve and PVA acceleration cause connection problems.

Last update date:

5/17/2024

Affected products:

BIG-IP

BIG-IP AFM

BIG-IP Install/Upgrade

Affected releases:

15.1.9

15.1.9.1

15.1.10

15.1.10.2

15.1.10.3

15.1.10.4

16.1.0

16.1.1

16.1.2

16.1.2.1

16.1.2.2

16.1.3

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1325681: VLAN tscookies with fastl4 timestamp preserve and PVA acceleration cause connection problems. ... Last Modified: May 17, 2024 ... Affected Product(s): ... Related Article: K000136894 ... Symptoms ... Some connections might be reset by the client or server when VLAN timestamp cookies are configured. ... Impact ... Unexpected flow RSTs from client/server due to incorrect timestamp echo received from BIG-IP. ... Either: - Set fastL4 profile option 'tcp-pva-whento-offload' to 'establish' OR - Disable VLAN timestamp cookies. ... OR - Change Bigproto timestamp option to rewrite (this disables PVA acceleration in a process). ... Fix Information