5/17/2024
BIG-IP
BIG-IP AFM
BIG-IP Install/Upgrade
15.1.9
15.1.9.1
15.1.10
15.1.10.2
15.1.10.3
15.1.10.4
16.1.0
16.1.1
16.1.2
16.1.2.1
16.1.2.2
16.1.3
No fixed releases provided.
Bug ID 1325681: VLAN tscookies with fastl4 timestamp preserve and PVA acceleration cause connection problems. ... Last Modified: May 17, 2024 ... Affected Product(s): ... Related Article: K000136894 ... Symptoms ... Some connections might be reset by the client or server when VLAN timestamp cookies are configured. ... Impact ... Unexpected flow RSTs from client/server due to incorrect timestamp echo received from BIG-IP. ... Either: - Set fastL4 profile option 'tcp-pva-whento-offload' to 'establish' OR - Disable VLAN timestamp cookies. ... OR - Change Bigproto timestamp option to rewrite (this disables PVA acceleration in a process). ... Fix Information