Standby tenant cannot access floating traffic group when MAC masquerade is enabled

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP F5OS

BIG-IP TMOS

BIG-IP Velos

Affected releases:

15.1.10

15.1.10.2

15.1.10.3

15.1.10.4

17.1.0.1

17.1.0.2

17.1.0.3

17.1.1

17.1.1.1

17.1.1.2

17.1.1.3

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1325737: Standby tenant cannot access floating traffic group when MAC masquerade is enabled ... Last Modified: Apr 26, 2024 ... Symptoms ... A standby BIG-IP tenant running on an r2000 or r4000 appliance cannot access addresses in the floating traffic group if MAC masquerade is enabled. ... For instance, the standby tenant will not be able to ping the floating self IP address. ... External devices can access the floating self IP address without issue. ... If the tenants swap HA roles (the active device becomes standby, and the standby device becomes active), the problem follows the standby device -- the newly-standby system is not able to ping the floating self IP address. ... Impact ... Standby tenant unable to access resources in the floating traffic group when MAC masquerade is configured. ... Conditions ... -- F5 r2000 or BIG-IP r4000 system -- BIG-IP tenant with MAC masquerade configured for floating traffic group