BugZero found this defect 201 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/26/2024
BIG-IP
BIG-IP F5OS
BIG-IP TMOS
BIG-IP Velos
15.1.10
15.1.10.2
15.1.10.3
15.1.10.4
17.1.0.1
17.1.0.2
17.1.0.3
17.1.1
17.1.1.1
17.1.1.2
17.1.1.3
No fixed releases provided.
Bug ID 1325737: Standby tenant cannot access floating traffic group when MAC masquerade is enabled ... Last Modified: Apr 26, 2024 ... Symptoms ... A standby BIG-IP tenant running on an r2000 or r4000 appliance cannot access addresses in the floating traffic group if MAC masquerade is enabled. ... For instance, the standby tenant will not be able to ping the floating self IP address. ... External devices can access the floating self IP address without issue. ... If the tenants swap HA roles (the active device becomes standby, and the standby device becomes active), the problem follows the standby device -- the newly-standby system is not able to ping the floating self IP address. ... Impact ... Standby tenant unable to access resources in the floating traffic group when MAC masquerade is configured. ... Conditions ... -- F5 r2000 or BIG-IP r4000 system -- BIG-IP tenant with MAC masquerade configured for floating traffic group