BugZero found this defect 282 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/26/2024
BIG-IP
BIG-IP LTM
15.1.0
15.1.0.1
15.1.0.2
15.1.0.3
15.1.0.4
15.1.0.5
15.1.1
15.1.2
15.1.2.1
15.1.3
15.1.3.1
15.1.4
No fixed releases provided.
Bug ID 1326797: The Pool State of an offline pool with one or more user-disabled pool members depends on which pool member was marked down last by its monitor (non-deterministic behaviour) ... Last Modified: Apr 26, 2024 ... Severity: 4-Minor ... Symptoms ... When you have two or more pool members with one pool member being administratively disabled and the other(s) being enabled, and all pool members are marked down by their monitor, the pool status depends on which pool member was marked down last. ... Specifically: - the disabled pool member is marked down by the monitor last - pool is in "offline/disabled-by-parent" state - one of the enabled pool members are marked down by monitor last - pool is in "offline/enabled" state ... Impact ... When all the pool members are marked down by their monitors, the State of the pool depends on which pool member was last marked down by its monitor. ... Conditions ... - LTM pool configured with two or more pool members - One pool member adminis...