F5 | 1328217

SSL Orchestrator may fail to finish upgrading from SSL Orchestratorv9.1 or SSL Orchestratorv9.2 if tcp profile exists with name that starts with sslo_ and ends with -tcp-lan

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP Install/Upgrade

BIG-IP SSLO

Affected releases:

16.0.0

16.0.0.1

16.0.1

16.0.1.1

16.0.1.2

16.1.0

16.1.1

16.1.2

16.1.2.1

16.1.2.2

16.1.3

16.1.3.1

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1328217: SSL Orchestrator may fail to finish upgrading from SSL Orchestratorv9.1 or SSL Orchestratorv9.2 if tcp profile exists with name that starts with sslo_ and ends with -tcp-lan ... Any configuration changes are not allowed till upgrade process is finished" ... Impact ... The upgrade gets stuck, and you are unable to make any SSL Orchestrator changes until the issue has been resolved. ... Conditions ... Upgrading from SSL Orchestratorv9.1 or 9.2 with a tcp profile that has the following conditions: 1. ... Has a name that starts with sslo_ 2. ... Has a name that ends with -tcp-lan 3. ... Workaround ... Delete the tcp profile with the above conditions. ... Change the tcp profile values a. Minimum RTO: 200 b. Nagle's Algorithm: Auto c. Slow Start: Enabled