F5 | 1347825

Traffic group becomes active on more than one BIG-IP after a long uptime and long HA disconnection time

Last update date:

5/16/2024

Affected products:

BIG-IP

BIG-IP LTM

Affected releases:

14.0.0

14.0.0.1

14.0.0.2

14.0.0.3

14.0.0.4

14.0.0.5

14.0.1

14.0.1.1

14.1.0

14.1.0.1

14.1.0.2

14.1.0.3

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1347825: Traffic group becomes active on more than one BIG-IP after a long uptime and long HA disconnection time ... Symptoms ... Traffic-groups become active/active after a long uptime interval and the HA connection is disconnected for longer than 30 seconds. ... Note: Uptime required to encounter this issue is dependent on the number of traffic groups: the more traffic groups, the shorter the uptime. ... Impact ... Outage due to traffic-group members being active on both systems at the same time. ... Conditions ... -- Two or more BIG-IP systems defined in a device group for sync/failover. -- There is one or more traffic groups configured. -- The BIG-IP systems have a long uptime. -- The BIG-IP systems lose their HA connection for more than 30 seconds. -- The issue is more likely to occur when the watchdog daemon sod uptime, normally the same as system uptime, is above (6.8 years / number of traffic groups ). ... There is no workaround. ... Either all the BIG-IP units need t...