Monitor status update logs unclear for FQDN template pool member

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP LTM

Affected releases:

14.1.0

14.1.0.1

14.1.0.2

14.1.0.3

14.1.0.5

14.1.0.6

14.1.2

14.1.2.1

14.1.2.2

14.1.2.3

14.1.2.4

14.1.2.5

Fixed releases:

No fixed releases provided.

Description:

[ ] [ was unknown for #hrs:##mins:##sec ] ... Although such log messages indicate the current state of the FQDN template pool member, the prior status is indicated as "unknown" and does not accurately indicate the prior state of the FQDN template pool member. ... Impact ... Such messages may confuse users who are attempting to monitor changes in the BIG-IP system by not providing clear information. ... Conditions ... This may occur when FQDN nodes and pool members are configured, and When the state of an FQDN template node is changed (such as being forced offline or re-enabled from an offline state by user action). ... Workaround ... The state of an FQDN template pool member is generally determined by the state of the referenced FQDN template node. ... The FQDN template node contains the configuration used to resolve the FQDN name to the corresponding IP addresses. ... FQDN template pool members are not involved in this process, and generally only reflect the status of the name reso...