Operational Defect Database

BugZero found this defect 223 days ago.

F5 | 1366593

HTTPS monitors can fail when multiple bigd processes use the same netHSM

Last update date:

5/8/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

15.1.0

15.1.0.1

15.1.0.2

15.1.0.3

15.1.0.4

15.1.0.5

15.1.1

15.1.2

15.1.2.1

15.1.3

15.1.3.1

15.1.4

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1366593: HTTPS monitors can fail when multiple bigd processes use the same netHSM ... Last Modified: May 08, 2024 ... Symptoms ... Monitors going down accompanied by netHSM FIPS errors in /var/log/ltm. Following is an example error: 01960005:3: netHSM: Shared memory error [Failed to fetch result]. ... Impact ... Intermittently seeing HTTPS monitors fail for brief periods, causing some pool members to briefly be marked down. ... Conditions ... HTTPS monitors having server_ssl profile that is storing a key in netHSM. ... Workaround ... Configure bigd to run in single process mode by running the following commands: tmsh modify sys db bigd.numprocs value 1 bigstart restart bigd ... Fix Information