Operational Defect Database

BugZero found this defect 181 days ago.

F5 | 1398809

TMM can not process traffic on Cisco ENIC

Last update date:

4/25/2024

Affected products:

BIG-IP

BIG-IP LTM

Affected releases:

11.6.0

11.6.1

11.6.2

11.6.3

11.6.3.1

11.6.3.2

11.6.3.3

11.6.3.4

11.6.4

11.6.5

11.6.5.1

11.6.5.2

Fixed releases:

No fixed releases provided.

Description:

- TMM cannot process traffic - Within '/var/log/tmm', there is the following log line rte_enic_pmd: Rq 0 Scatter rx mode not being used - 'tmctl -d blade tmm/xnet/dpdk/stats' stat table shows a large (several 10000) for 'mbuf_inuse' and 'frag_inuse', and 'mbuf_alloc_fail' is an extremely large count (in the scale of millions) and continuously increasing ... Impact ... Traffic disrupted as TMM is not able to receive nor send packets. ... Conditions ... - TMM is using Xnet-DPDK drivers - BIG-IP is connected to a Cisco ENIC card In addition to the above, one or both of the following a) Only 1 RX queue available b) MTU <= 1920 By default, TMM will set MTU to 1500 for ENIC. ... Workaround ... Both of following must be done: 1) Configure ENIC to have 2 or more RX queues available 2) Create a file '/config/tmm_init.tcl' containing the following line: ndal mtu 9000 1137:0043 ... Fix Information ... None

Additional Resources / Links