External IDP Connector Certificate Settings disappears

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP APM

Affected releases:

16.1.3

16.1.3.1

16.1.3.2

16.1.3.3

16.1.3.4

16.1.3.5

16.1.4

16.1.4.1

16.1.4.2

16.1.4.3

17.1.0

17.1.0.1

Fixed releases:

No fixed releases provided.

Description:

When BIG-IP administrator creates a certificate with name "SP_ADFS__saml_idp_metadata_cert.crt", the dropdown showing the list of available certificates in the External IDP Connector Settings disappeared. ... Impact ... The BIG-IP administrator will not be able to select a certificate for External IDP Connector. ... Conditions ... The issue occurs only when the certificate is named with string "SP_ADFS__saml_idp_metadata_cert.crt" ... Workaround ... As the issue occurs only for chrome & Edge browsers, the BIG-IP administrator can use Safari or FireFox. ... Fix Information ... None