4/26/2024
BIG-IP
BIG-IP APM
16.1.3
16.1.3.1
16.1.3.2
16.1.3.3
16.1.3.4
16.1.3.5
16.1.4
16.1.4.1
16.1.4.2
16.1.4.3
17.1.0
17.1.0.1
No fixed releases provided.
When BIG-IP administrator creates a certificate with name "SP_ADFS__saml_idp_metadata_cert.crt", the dropdown showing the list of available certificates in the External IDP Connector Settings disappeared. ... Impact ... The BIG-IP administrator will not be able to select a certificate for External IDP Connector. ... Conditions ... The issue occurs only when the certificate is named with string "SP_ADFS__saml_idp_metadata_cert.crt" ... Workaround ... As the issue occurs only for chrome & Edge browsers, the BIG-IP administrator can use Safari or FireFox. ... Fix Information ... None