5/10/2024
BIG-IP
BIG-IP LTM
15.1.4
15.1.4.1
15.1.5
15.1.5.1
15.1.6
15.1.6.1
15.1.7
15.1.8
15.1.8.1
15.1.8.2
15.1.9
15.1.9.1
No fixed releases provided.
Bug ID 1400001: PVA dedicated mode does not accelerate all connections ... Last Modified: May 10, 2024 ... Severity: 3-Major ... Symptoms ... While in PVA dedicated mode, all flows may not be fully accelerated because neuron rules are not created for flow collisions. ... Impact ... Higher latency for these connections because they are not in PVA. ... Conditions ... A fastL4 profile with pva-acceleration set to "dedicated. ... sys turboflex profile-config set to "turboflex-low-latency" This type of configuration is commonly used for hardware-optimized FIX low latency electronic trading traffic. ... Workaround