Operational Defect Database

BugZero found this defect 164 days ago.

F5 | 1400001

PVA dedicated mode does not accelerate all connections

Last update date:

5/10/2024

Affected products:

BIG-IP

BIG-IP LTM

Affected releases:

15.1.4

15.1.4.1

15.1.5

15.1.5.1

15.1.6

15.1.6.1

15.1.7

15.1.8

15.1.8.1

15.1.8.2

15.1.9

15.1.9.1

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1400001: PVA dedicated mode does not accelerate all connections ... Last Modified: May 10, 2024 ... Severity: 3-Major ... Symptoms ... While in PVA dedicated mode, all flows may not be fully accelerated because neuron rules are not created for flow collisions. ... Impact ... Higher latency for these connections because they are not in PVA. ... Conditions ... A fastL4 profile with pva-acceleration set to "dedicated. ... sys turboflex profile-config set to "turboflex-low-latency" This type of configuration is commonly used for hardware-optimized FIX low latency electronic trading traffic. ... Workaround

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Resolved

Learn More