F5 | 1401961

A blade with a non-functional backplane may override the dag context for the whole system

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

15.1.0

15.1.0.1

15.1.0.2

15.1.0.3

15.1.0.4

15.1.0.5

15.1.1

15.1.2

15.1.2.1

15.1.3

15.1.3.1

15.1.4

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1401961: A blade with a non-functional backplane may override the dag context for the whole system ... Last Modified: Apr 26, 2024 ... Symptoms ... A blade with a non-functional backplane may override the dag context for the whole system. ... Impact ... The traffic is black-holed into a non-functional blade. ... Conditions ... - a blade has backplane problems, as evidenced by "shared random" not being ready in `tmctl -d blade tmm/ready_for_world_stat`. ... Workaround ... Depending on the nature of the blade fault, a workaround is to either disable or just reboot the non-functional blade. ... Fix Information