F5 | 1404253

[NAT-LOGS] PBA Lease Duration suffers from a 32-bit rollover after 50 days

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP AFM

Affected releases:

15.1.0

15.1.0.1

15.1.0.2

15.1.0.3

15.1.0.4

15.1.0.5

15.1.1

15.1.2

15.1.2.1

15.1.3

15.1.3.1

15.1.4

Fixed releases:

No fixed releases provided.

Description:

Severity: 3-Major ... Symptoms ... On NAT logs, the sum of PBA start time and duration values do not match with the log-generated time. ... Impact ... The duration field in the logs does not show the right value. ... Conditions ... NAT policy in action with PBA and block-life-time is 0 which implies infinite time. ... Workaround ... None