Operational Defect Database

BugZero found this defect 164 days ago.

F5 | 1408229

VCMP guest deployment may fail on newly installed blade

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP vCMP

Affected releases:

14.1.0

14.1.0.1

14.1.0.2

14.1.0.3

14.1.0.5

14.1.0.6

14.1.2

14.1.2.1

14.1.2.2

14.1.2.3

14.1.2.4

14.1.2.5

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1408229: VCMP guest deployment may fail on newly installed blade ... Symptoms ... If a VCMP guest is configured to be Provisioned or Deployed to multiple blades in a VIPRION chassis, and one of those blades is replaced or has a new installation of BIG-IP installed, the VCMP guest may fail to be Provisioned or Deployed to the newly installed/reinstalled blade. ... A message similar to the following may be logged to the LTM log (/var/log/ltm): <date> <time> slot# err vcmpd[##### ... Impact ... The VCMP guest fails to be Provisioned or Deployed to the newly installed/reinstalled blade. ... Conditions ... This may occur if: -- VCMP is provisioned, and one or more VCMP guests are provisioned/deployed in a VIPRION chassis with multiple blades. -- One of the blades is replaced with a new blade (such as from an RMA replacement). -- The newly installed/reinstalled blade has a version of BIG-IP installed that does not match the BIG-IP version installed and running on the existing blade...