The chmand fails to fully start on multi-slot F5OS tenants when the cluster members have addresses or alternate addresses

Last update date:

5/9/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

15.1.8

15.1.8.1

15.1.8.2

15.1.9

15.1.9.1

15.1.10

15.1.10.2

15.1.10.3

15.1.10.4

17.1.1

17.1.1.1

Fixed releases:

17.1.1.2

Description:

Bug ID 1409537: The chmand fails to fully start on multi-slot F5OS tenants when the cluster members have addresses or alternate addresses ... The chassis manager daemon (chmand) is wedged and does not fully start causing MCPD and cluster to never start. ... Impact ... The slot does not come online and stays inoperative. ... Conditions ... This issue is seen when IPv6 alternate addresses to the cluster members are added and rebooted to a slot. ... Workaround ... Fix Information ... Using the copy of a variable for a bad iterator has fixed the issue. ... Behavior Change